Industrial flooring · System 01

Epoxy Floor Coatings

The most widely preferred flooring system for production and storage areas where mechanical strength, chemical resistance and hygiene are required together.

Why epoxy

There is a reason it is the industry’s default floor.

An epoxy floor coating is not a colored surface painted onto concrete. It is a system that bonds with the concrete and forms a dense, non-porous shell, protecting the floor against abrasion, impact and chemical contact. Its hardness, cleanability and wide range of use make it the first solution that comes to mind for industrial floors.

For most production and storage areas, epoxy is the right starting point. If your facility’s conditions have a more specific character, for example continuously wet and hot processes, sudden temperature changes or a need for high flexibility, you will find a short comparison at the end of this page pointing you to the right system.

What sets epoxy apart
  • Hard, durable surface: Handles intensive pedestrian and vehicle traffic and heavy loads.
  • Chemical resistance: Provides protection against many chemicals and spills.
  • Non-porous and hygienic: Easy to clean, does not hold dust, inhospitable to bacteria.
  • Wide range of options: Adaptable from thin coatings to heavy-duty screeds.
Where it is used

The floor of dry, general-purpose production environments.

Epoxy systems are preferred across a wide range of areas where mechanical and chemical resistance is the priority and ambient conditions are balanced.

Area 01

Production halls

Manufacturing and assembly areas in constant use.

Manufacturing · Assembly
Production halls
Area 02

Warehousing and logistics

Racking systems, forklift traffic and loading areas.

Racking · Forklifts
Warehousing and logistics
Area 03

Parking and circulation

Surfaces exposed to vehicle traffic and constant wear.

Vehicle traffic
Parking and circulation
Area 04

Technical and service rooms

Maintenance, workshop and equipment areas.

Workshop · Service
Technical and service rooms
Area 05

General manufacturing areas

Multi-purpose production floors operating under balanced conditions.

Multi-purpose
General manufacturing areas
Area 06

Showrooms and exhibitions

Clean, even surfaces where aesthetics also matter.

Commercial · Exhibition
Showrooms and exhibitions
Finish coat Body coat Primer Surface preparation Concrete slab
Representative system cross-section · layer sequence
System cross-section

Not a single surface but a layered system.

The performance of an epoxy floor depends less on the visible top surface than on the correct build-up of the layers beneath it. Each layer takes on a different duty, and they work together.

  • Finish coatDefining the surface’s appearance, texture and cleanability, the topmost protective layer.
  • Body coatCarrying the mechanical strength, with thickness set by the facility’s loads, the main layer.
  • PrimerThe bonding layer between the concrete and the coating, providing the adhesion of the whole system.
  • Surface preparationWhere the concrete is mechanically cleaned and profiled: the stage that determines the adhesion of the entire system.
  • Concrete slabThe existing substrate the system is built on, its condition assessed beforehand.
System options

One material family, different applications.

Epoxy is not a single product but a family of systems adapted to the facility’s loads and expectations.

01

Thin-film coating

An economical thin layer that prevents dusting and protects the surface.

Light use
02

Self-leveling

A flow-applied system that produces a smooth, seamless surface.

Medium to heavy use
03

Aggregate broadcast

Heavy-duty areas requiring high thickness and mechanical strength.

Heavy loads
04

Anti-slip textured

A textured finish giving the surface grip for safety.

Safety first
Key properties

What is expected of an epoxy floor.

High mechanical strength

Long life under intensive traffic, impact and abrasion.

Chemical resistance

Protection against many chemicals and spills.

Non-porous surface

A dense surface preventing liquids and chemicals from penetrating the concrete.

Easy to clean

A low-maintenance surface fit for hygiene audits.

Dust-free

Prevents concrete dusting and keeps the environment clean.

Color and aesthetics

A wide color range and a neat, professional appearance.

Typical thickness

Thickness that scales with the need.

The values below are indicative typical ranges only. The final system and thickness are determined by assessing the facility’s load, chemical and usage conditions on site.

Thin filmprotective coating
Self-levelingapproximately 2 – 3 mm
Aggregate broadcastheavy duty

Technical documents for members

Technical data sheets, safety data sheets and application specifications are available in the membership area open to corporate clients, architects and engineers. Access is free with membership.

Member login →
Direct contact

Let’s determine the right floor for your facility, together.

Share the conditions your floor needs to withstand, and we will assess the site and propose the right system.

Scroll to Top