Industrial flooring · System 03

Sika Ucrete Systems

Polyurethane-cement heavy-duty systems for the most demanding environments: food and beverage production, wet processes and sudden temperature changes.

Why Sika Ucrete

The flooring world’s answer to the harshest conditions.

Sika Ucrete is a flooring system developed for heavy-duty conditions, combining polyurethane with cement. In production areas washed with hot water and steam, exposed to sudden temperature changes and in constant contact with oils and chemicals, it steps in where epoxy and standard polyurethane reach their limits.

In food and beverage production in particular, it is the first choice for areas where hygiene and thermal shock resistance are required together. If your conditions are not this demanding, a more economical epoxy or polyurethane system may also be sufficient.

What sets Sika Ucrete apart
  • Thermal shock resistance: Withstands sudden temperature changes and hot-water washdowns.
  • Heavy mechanical loads: Long life under intensive forklift traffic and impact.
  • Chemical resistance: Protection against oils, acids and aggressive chemicals.
  • Hygiene: An easy-to-clean surface fit for food safety.
Where it is used

The floor of the most demanding production conditions.

Sika Ucrete is designed for areas where temperature, wetness, loads and chemicals push the floor all at once.

Area 01

Food production areas

Production lines where hygiene and durability are required together.

Food production
Food production areas
Area 02

Beverage and bottling

Continuously wet, intensively washed facilities.

Beverage
Beverage and bottling
Area 03

Cold storage rooms

Areas exposed to low temperatures and thermal movement.

Cold storage
Cold storage rooms
Area 04

Wet process and washdown

Sections with intensive water, steam and heat.

Wet process
Wet process and washdown
Area 05

Industrial kitchens

Areas where grease, heat and hygiene are critical.

Kitchens
Industrial kitchens
Area 06

Chemical-contact production

Floors in constant contact with aggressive chemicals.

Chemical contact
Chemical-contact production
Seal coatSika Ucrete screedPrimerSurface preparationConcrete slab
Representative system cross-section · layer sequence
System cross-section

Thick, integrated protection.

Sika Ucrete is not a thin coating but a thick protective layer that becomes one with the concrete; its durability comes from this thickness and structure.

  • Seal coatSealing the surface and defining its cleanability, the top layer.
  • Sika Ucrete screed layerTaking the thermal shock and heavy loads, the thick polyurethane-cement layer.
  • PrimerThe bonding layer reinforcing adhesion to the concrete.
  • Surface preparationWhere the concrete is mechanically cleaned and profiled: the stage that determines the adhesion of the entire system.
  • Concrete slabThe existing substrate the system is built on, its condition assessed beforehand.
System options

Heavy-duty options to suit the conditions.

Sika Ucrete is applied in different build-ups according to the area’s temperature and hygiene expectations.

01

Standard screed system

A thick protective layer for general heavy duty.

Heavy duty
02

Self-leveling

A smooth, hygienic top surface.

Hygiene
03

Anti-slip textured

A texture providing safe grip in wet areas.

Wet-area safety
04

High-temperature grade

A build-up resistant to hot water and steam washdowns.

Thermal shock
Key properties

What is expected of a Sika Ucrete floor.

Thermal shock resistance

Withstands sudden temperature changes and hot-water washdowns.

Heavy mechanical loads

Long life under intensive forklift traffic and impact.

Chemical resistance

Protection against oils, acids and aggressive chemicals.

Hygienic surface

A cleanable surface fit for food safety.

Watertight

A safe floor in wet, washed-down areas.

Long service life

Lasting performance even under demanding conditions.

Typical thickness

Its thickness comes from the conditions it faces.

The values below are indicative typical ranges only. The final system and thickness are determined by assessing the facility’s conditions on site.

Seal coatthin top surface
Standard screedapproximately 4 – 6 mm
Heavy dutygreater thickness

Technical documents for members

Technical data sheets, safety data sheets and application specifications are available in the membership area open to corporate clients, architects and engineers. Access is free with membership.

Member login →
Direct contact

Let’s determine the right floor for your facility, together.

Share the conditions your floor needs to withstand, and we will assess the site and propose the right system.