Special systems · Type 01

Passive Fire Protection

Systems that delay the spread of fire and smoke through the building, protecting compartment integrity from cable and pipe penetrations to joints.

Why passive fire protection

In a fire, time is won inside the walls.

The visible face of fire safety is the alarms and suppression systems; the invisible face is the building itself. A fire-rated wall loses its function through a single unsealed cable tray or pipe penetration passing through it; flame and smoke use the smallest gap like a corridor. Passive fire protection closes these gaps against fire and smoke, restoring the integrity of the compartment.

This is not a filling job but a systems job: the right system is selected according to the type of penetration, the fire resistance rating of the wall or slab, and the behavior of the services passing through. In our applications, every penetration is labeled together with the system used and put on record, because a firestopping application gains its full value through its auditability.

What sets this system apart
  • Compartment integrity: The designed function of the fire compartments is preserved at the penetration points.
  • A system per penetration type: The right solution for cables, pipes, ducts and joints, each in its own right.
  • Labeled, recorded handover: Every penetration is documented; traceability is provided for audits.
  • Application in live facilities: Zoned, planned application in operating facilities.
Where it is used

At every point where a fire compartment is breached.

Passive fire protection is on the agenda wherever services pass through the building’s compartments.

Penetration 01

Cable tray penetrations

Cable routes passing through walls and slabs.

Cables · Trays
Cable tray penetrations
Penetration 02

Pipe penetrations

Compartment penetrations of combustible and non-combustible pipes.

Pipes · Services
Pipe penetrations
Penetration 03

Ventilation ducts

Perimeter sealing of duct penetrations.

Ducts · HVAC
Ventilation ducts
Penetration 04

Structural joints

Sealing of compartment wall and slab joints.

Joints · Compartments
Structural joints
Penetration 05

Floor-crossing shafts

Dividing vertical shafts between floors.

Shafts · Vertical
Floor-crossing shafts
Penetration 06

Blank openings

Temporary and permanent closing of reserved openings.

Reserves · Openings
Blank openings
Firestop sealantFire-resistant fillingService penetrationFire compartment (wall / slab)
Representative penetration detail · system components
System cross-section

The gap is closed; the resistance rating is restored.

The gap around the penetration is closed with materials that react to fire; the system restores the compartment’s resistance rating.

  • Firestop sealantThe finish providing the seal against smoke at the surface.
  • Fire-resistant fillingThe body filling the gap and preserving its integrity under heat.
  • Service penetrationThe cable, pipe or duct that defines the system by its type.
  • Fire compartmentThe wall or slab whose resistance rating is defined in the design.
System options

A system for the type of penetration.

System selection is defined by the penetration type, the compartment’s resistance rating and the services’ behavior.

01

Sealant and filling systems

Perimeter sealing of pipe and cable penetrations.

Point penetrations
02

Firestop pillows

A removable, re-usable solution for changing services.

Flexible penetrations
03

Intumescent systems

Components that expand with heat to close the gap.

Combustible pipes
04

Joint tapes and sealants

Continuity sealing of compartment joints.

Joints
Key properties

What is expected of a firestopping system.

Integrity against flame

The compartment’s resistance rating is preserved at the penetration.

Smoke sealing

The passage of smoke is brought under control.

Approved systems

Tested, certified system components.

Labeled records

Every penetration is labeled and reported.

Planned application

Zoned work while operations continue.

Audit readiness

Handover with a traceable file.

Scope of application

The scope follows the facility’s compartment layout.

The classification below is indicative only. The final scope is determined by the building’s fire compartmentation design and the site survey.

Point penetrationsindividual service points
Zone-based programsby floor or by section
Facility-wide programsall compartment penetrations